KWX-ATS16A8C3-H3

£640.00 excl: VAT

PDU eXperts KWX Automatic Transfer Switches (ATS) seamlessly switch loads between primary and backup power sources, this combined with real time power monitoring and built in environmental monitoring makes it one of the most advanced transfer switches on the market.

KWX-ATS16A8C3-H3 – 8 port,  2 x 16A Input plugs A & B connection ( 8 x lockable IEC-C13), 19" rack mountable intelligent automatic transfer switch.

 

KWX-ATS16A8C3-H3 - 8 port,  2 x 16A Input plugs A & B connection ( 8 x lockable IEC-C13), 19" rack mountable intelligent automatic transfer switch.

PDU eXperts KWX Automatic Transfer Switches (ATS) seamlessly switch loads between primary and backup power sources, this combined with real time power monitoring and built in environmental monitoring makes it one of the most advanced transfer switches on the market.

In the event where the primary power source becomes unavailable, the KWX ATS will flawlessly source power from the secondary source without interrupting sensitive equipment, the switching occurs in just 8ms safely between the two input sources regardless of their phase.

PDU eXperts intelligent KWX-ATS management software enables the administrator to give designated users predetermined control over whole ATS units or even single outlets over a range of ATS units. Users have the ability to monitor and control directly through the ATS units network module on site, or remotely using our embedded multithreading inner core “Real time operating systems” (RTOS) software.  The management software is accessible within the data centres secure hardwired network, supporting various TCIP/IP protocols, including HTTP, HTTPS, SSL, SNMP versions 1,2 & 3, TELNET, SSH, SMTP and NTP from any network PC or laptop.

Key Features:

  • Adjustable sequential powering (on/off)
  • Total current monitoring
  • Outlets Switching ON/OFF
  • Adjustable sequential powering (on)
  • 8 millisecond Switch over
  • Total current monitoring
  • Total voltage input & output monitoring
  • Total kWh used
  • Power factor recognition
  • Up to 55°C Hot aisle operating capacity 
  • SMS, SNMP & Email
  • Effortless user friendly PDU management interface
  • Control up to 3 KWX slaves from a master KWX PDU
  • 2 x C20 Input plugs A & B connection
  • 8 x IEC C13 lockable IEC-C13 Outlets

Built in environmental monitoring as standard:

  • Temperature & humidity alarm sensor
  • Water logging alarm sensor
  • Infrared sensor (for Intrusion & detect) 
  • Smoke detector
  • Automated alarm notifications
  • Up to 8 plug and play sensors
  • Lockable IEC C13 sockets as standard
  • Intelligent outlet type and recognition
  • 24v & 48v DC, Single phase 120v & 240v & 3 phase 400v